Okay, so while installing the RAC one of the primary OS drive cradles must have been nudged enough to either disconnect the drive or the tray was not fully seated in the first place.

Either way we ended up with a Critical error on the OS’s RAID 1 array.

The BIOS for the “RAID” at the motherboard level holds no clues to how to rebuild the array once we re-seated the drive.

We booted the server since our experience with software based on board RAID chipset failures require the driver to be loaded and available before a rebuild could be initiated (some Intel on board RAID chipsets are an exception to this rule).

Once into the OS we found the AMD RAIDXpert “console” link:

image

What came up was a Web based console that asked for a username and password. Fortunately the default username and password was right there on the logon page.

Once in we were able to initiate a rebuild of the RAID 1 array:

image

The rebuild time for a pair of 750GB Seagate ES series drives took quite a few hours on this particular box even though there was not a lot of disk action going on via the network.

The Performance tab in the Task Manager during the rebuild process looked like this:

image

Philip Elder 
MPECS Inc. 
Microsoft Small Business Specialists 
Co-Author: SBS 2008 Blueprint Book

Fuente: http://blog.mpecsinc.ca/2011/04/hp-proliant-microserver-rebuilding.html

 

Camino de las Aguas 1037003 - Salamanca (España)
923282726 (WhatsApp)
923282726 (Llamar)
Horario: 9:00 a 14:00hTardes cita previa
Boletín de Noticias

© 2026 PROMOCIONALIA más que informática. – Ordenadores, Portátiles, Tablets, Accesorios. Servicio Técnico, Mantenimiento Empresas. Diseño páginas web, Email, Dominios, Hosting. Marketing digital, Social Media Management. Rotulación en vinilo. Distribuidor Fibra y móvil: O2 / Simyo / Digi / Masmovil. Venta, Reparación y Alquiler de Máquinas Arcade Retro. Más de 25 años de experiencia, desde 1997 hasta hoy.